Digital Permeability Meter VPD II

The Digital Permeability Meter VPD II measures absolute permeability of foundry sand on a standard AFS (2 in x 2 in) or metric (50 mm x 50 mm) specimen. With the relevant attachments it also measures relative permeability of moulds…

Request a quote

Description

The Digital Permeability Meter VPD II measures absolute permeability of foundry sand on a standard AFS (2 in x 2 in) or metric (50 mm x 50 mm) specimen. With the relevant attachments it also measures relative permeability of moulds and absolute permeability of cores and unbonded sand. Ethernet (RJ45) output and cloud sync via V-Sync.

Calibration guide: How to calibrate a permeability meter
Verify a calibration certificate: cal.sandtesting.org

1.1 General information

This is a precision equipment to measure Permeability of Foundry Sands. By default it can measure absolute permeability of an AFS (Dia. 2”X2”) or Metric (Dia. 50mmX50mm) Specimen.

With Help of attachment it can also measure

  • Relative Permeability of Moulds (Refer 4.2.1)
  • Absolute Permeability of Cores (Refer 4.2.2)
  • Absolute Permeability of Un-bonded sand (Refer 4.2.3).

1.2 General Usage

Specimen held in a Tube or accessory is placed on the measuring Rubber Boss. On press of start button, within few seconds the equipment shows Permeability reading.

1.3 Product Data

Product Name:

Digital Permeability Meter

Product Code:

VPD II

Order Reference Code:

V0000109

Electrical Supply Required:

230v 50Hz A.C. (Default)

110v 60 Hz A.C (Optional)

Single Phase, Stabilized with Over/ Under Voltage cut-off.

Electrical Plug:

M type : 15 Amp Plug

Typical Maximum Current:

1.5 A at 230V

Compressed air Supply:

Required 2 Kg/cm2 Dry Compressed Air to make the operations fully automatic.

Optional if Air Drum can be lifted by Operator.

Communication:

  • Ethernet (RJ45)
  • Cloud Sync using V-Sync

Dimensions:

535x330x475 mm (WXBXH)

Packing Dimensions:

640x440x600 mm

(WXBXH) Typical

Net Weight:

Approximately 30 kg

Gross Weight:

Approximately 40 kg

Colour:

Factory Default

Measuring Range:

0-100 mmWC and Related readings AFS Permeability measurement chart digitally displayed.

Traceable to:

Manufacturers Standards

Least Count:

0.1 cmWC

Specimen Requirements:

Compression type specimen

Operating Temperature:

0-500C

Testing Standards:

BIS: Standard

AFS: Optional

(for standard specimen)

Calibration Frequency:

22500 nos. of Testing Cycles or Once in Year

2.1 Scope of supply

  • Digital Permeability Meter.
  • Large Orifice.
  • Syphon Pump.
  • Calibration certificate.
  • Instruction manual.

3.1 Recommended pre-requisite equipment

Sand Splitter : To get representative sample

Specimen preparation equipment’s to make a standard AFS or Metric specimen.

4.1 Recommended Calibration kits

There are four types of calibration kits to choose from:

VKPA: With Std. Specimen type for Small Orifice

VKPB: With Std. Specimen type for Large Orifice

VKPC: With Rubber Boss type for Small Orifice

VKPD: With Rubber Boss type for Large Orifice

4.2 Recommended attachments

VPR: Mould Perm Tester

VD: Core Permeability Tube

VBP: Base Permeability Tube

Small Orifice

4.3 Alternative equipment

Digital Permeability Meter VPD

Digital Permeability Meter VPD I

VCAT Multi Tester